Plumbing, Heating & Electrical Supplies for Trade and DIY
Next Working Day Delivery Available — Order Before 1pm!
Free Standard Delivery on Eligible Orders Over £150
Plumbing, Heating & Electrical Supplies for Trade and DIY
Next Working Day Delivery Available — Order Before 1pm!
Free Standard Delivery on Eligible Orders Over £150
Underfloor Heating Blending Valve and Pump Set (20°C - 55°C)

Underfloor Heating Blending Valve and Pump Set (20°C - 55°C)

Brand: MEP Stock
Code: ZL-2597
In Stock
PRODUCT OVERVIEW
Underfloor Heating Blending Valve and Pump Set - 20-55 Degrees C

The Underfloor Heating Blending Valve and Pump Set - 20-55 Degrees C is a professional heating circulation component designed to support circulation and control within a compatible water-based heating system. It is presented with the stated size, output, connection or configuration so installers and buyers can identify the required option accurately.

£183.75Ex. VAT

Product Options

IN STOCK
Price£66.50
Price£173.25
Price£183.75
Technical Fact Sheet BS EN 1264 | 20°C–55°C | 210mm Manifold Centres

What is the MEP Stock UFH Blending Valve & Pump Set (20°C–55°C)?
The MEP Stock Underfloor Heating Blending Valve and Pump Set (MEP-1188B-1F-2) is a pre-assembled, BS EN 1264 compliant hydraulic mixing unit engineered to step down high-temperature boiler flow water (up to 90°C) to safe, constant underfloor heating temperatures between 20°C and 55°C. Equipped with an ErP A-rated 6m circulation pump and standard 210mm manifold centres, it serves up to 14 kW (approx. 140–180 m²) and is a direct trade replacement for Grundfos UPM3 and Wilo Para manifold packs.

Temp Range: 20°C to 55°C
Manifold Centres: 210mm (1" BSP)
Max Output: Up to 14 kW (12 Ports)
Equivalents: Grundfos UPM3 / Wilo Para

Quick Trade Summary: Underfloor Heating Blending Valve and Pump Set (20°C - 55°C)

The Underfloor Heating Blending Valve and Pump Set 20°C - 55°C (ZL-2597) is an advanced hydronic mixing station engineered for low-temperature heat pump primaries and traditional condensing boilers alike. With an ultra-wide control band down to 20°C, it allows gentle initial commissioning screed curing (BS EN 1264-4) and ultra-low floor warming without thermal shock.

20°C - 55°C ULTRA-WIDE RANGEHEAT PUMP READY (LOW TEMP)A-RATED CIRCULATION PUMP1" BSP MANIFOLD UNIONSCW617N DZR BRASS

Trade Engineering Standards & Hydraulic Application

In hydronic underfloor heating installations, matching the circulation pump's head and volumetric flow rate to circuit pressure drop is essential to prevent cold spots, actuator noise, and premature component wear. The Underfloor Heating Blending Valve and Pump Set (20°C - 55°C) is precision-engineered to British Standard BS EN 1264 and CIBSE hydronic sizing standards, guaranteeing balanced loop flow across modern UK domestic and commercial heating systems.

Engineering Specifications & Technical Standards

Parameter Specification Standard
Model / SKUZL-2597 Wide-Range Mixing Set
Temperature Adjustment Band20°C to 55°C (Ultra-Wide Low-Temperature Range)
Primary Boiler Connections3/4" BSP Female Ports
Manifold Mounting Connections1" BSP Male Swivel Union Connectors (210mm Centres)
Circulation Pump IncludedHigh-Efficiency A-Rated 6m Circulating Pump
Flow Temperature GaugeDual Scale Dial (0°C to 80°C)
Body MaterialDezincification Resistant (DZR) Brass CW617N
Maximum Test Pressure10 Bar Static PN10
Heat Source CompatibilityAir Source Heat Pumps, Ground Source, Gas/Oil Boilers, Biomass
CertificationsBS EN 1264-4 Screed Curing Compliant, CE, UKCA

BS EN 1264 Floor Finish Flow Temperature Settings

Use the empirical commissioning table below to dial in the thermostatic blending valve head according to the finished floor covering and screed construction:

Floor Construction / Finish Recommended Flow Temp Max Surface Temp Design ΔT (Flow–Return)
Ceramic Tile / Stone on Screed45°C – 50°C29°C (35°C perimeter)7°C – 10°C
Engineered Wood / Laminate38°C – 42°C27°C Max (Strict)5°C – 7°C
LVT / Vinyl Flooring35°C – 40°C27°C Max (Adhesive Limit)5°C – 7°C
Low-Profile / Joist Spreader Plates50°C – 55°C29°C7°C – 10°C

Step-by-Step Installation & Commissioning Protocol

  1. Hydraulic Isolation & Depressurisation: Close manifold isolation ball valves and isolate primary boiler feeds before loosening union nuts. Have a trade catchment tray ready for residual water.
  2. Gasket Seating & Mechanical Fit: Inspect flat union mating faces. Insert fresh 1½" EPDM sealing washers. Position pump body strictly with the motor shaft horizontal (never pointing vertically up or down) to ensure water-lubricated bearing longevity.
  3. Torque Alignment: Tighten 1½" BSP union nuts by hand, then secure with adjustable pump spanners to recommended torque (approximately 45–55 Nm). Do not overtighten or pinch the rubber gasket.
  4. Electrical Termination: Wire live, neutral, and earth into the manifold wiring centre or 230V room thermostat switched live output. Verify earth continuity in accordance with BS 7671 (IET Wiring Regulations 18th Edition).
  5. Venting & Air Purging: Fill the manifold circuits loop by loop until flowmeter sight glasses run crystal clear of trapped microbubbles. Power on pump and allow automatic air-venting routine to complete before locking final operational mode.
  6. Flow Balancing: Calibrate flowmeters on each manifold port according to CIBSE design calculation sheets (typically 1.5 to 2.5 Litres/min per loop depending on loop length).
Complete UFH Plant Room

Building a Full Multi-Zone Underfloor Heating System?

Pair this 210mm pump & blending pack with our stainless steel UFH manifolds, PERT-AL-PERT barrier pipe, and 22mm/28mm copper press fittings.

Frequently Asked Questions: Underfloor Heating Blending Valve and Pump Set (20°C - 55°C)

Why is the 20°C to 55°C low-temperature range important for new screed?

BS EN 1264-4 mandates that newly laid screed must be cured slowly starting at 20°C–25°C for 3 days before increasing gradually. Standard mixing valves that start at 35°C can cause catastrophic screed cracking.

Will this mixing set mount directly to standard underfloor heating manifolds?

Yes, it features standard 1" BSP swivel union nuts with 210mm vertical centre-to-centre spacing, mounting directly onto flow and return manifold bars.

Is this mixing set compatible with heat pumps?

Yes, its high-Kv low-restriction valve body allows heat pumps running at 35°C–45°C to deliver maximum COP efficiency without excessive hydraulic throttling.

Does the set include the flow temperature thermometer?

Yes, an integrated dial thermometer is pre-installed on the mixed flow manifold connection for real-time visual temperature verification.

What direction does the pump circulate water?

The pump pulls blended water through the thermostatic valve and pushes it downwards into the lower flow manifold bar, with return water returning into the upper bar.

Can the mixing station be mounted on either the left or right of the manifold?

Yes, the modular brass body can be reversed for left-hand or right-hand manifold configuration on-site.

Order the Underfloor Heating Blending Valve and Pump Set (20°C - 55°C) with Trade Delivery

Genuine heating and hydronic supplies in stock for immediate dispatch. Backed by full UK manufacturer warranty and dedicated technical support.

Direct Compatibility & Equivalent Replacement Part Numbers

This UFH Blending Valve & Pump Set (20°C - 55°C) is engineered to BS EN 1264 standards with standard 1" BSP (G 1") male union connections at 210mm port centres. It provides a direct drop-in replacement or equivalent specification for leading UK trade underfloor heating control units:

Brand / System Equivalent Part Number Fitment Compatibility
Grundfos / Standard UFH UPM3 Auto 15-70 / UPM3 Flex AS Direct 130mm pump body drop-in
Wilo / Yonos PARA Yonos PARA RS 15/6 RKA / 25/6 Direct 130mm port-to-port replacement
Emmeti / TM3 Control Pack U9700040 / U9700050 Matches standard 210mm manifold rail spacing
Altecnic / Caleffi UFH 502-1053 / SATKF0019 Full functional equivalent (20–55°C range)
Reliance Water Controls (RWC) Thermoguard / UFH Control Pack UFH90001 Direct thread & temperature curve match

Installation Note: Always flush pipework in accordance with BS 7593 prior to commissioning replacement pumps.