Underfloor Heating Blending Valve and Circulation Pump Set

The Underfloor Heating Blending Valve and Circulation Pump Set is a professional heating circulation component designed to support circulation and control within a compatible water-based heating system. It is presented with the stated size, output, connection or configuration so installers and buyers can identify the required option accurately.

£178.50Ex. VAT

Product Options

Standard
Ex. VAT
IN STOCK
Price£64.60
Price£132.60
Price£136.00
IN STOCK
Price£151.30
IN STOCK
Price£168.30
IN STOCK
Price£178.50

Quick Trade Summary: Underfloor Heating Blending Valve and Circulation Pump Set (Complete Station)

The Underfloor Heating Blending Valve and Circulation Pump Set (ZL-2536W) is the premier complete manifold control station for UK underfloor heating systems. Built with solid forged DZR brass and featuring an integrated thermostatic mixing valve (35°C–65°C), high-efficiency A-rated 6m circulation pump, flow and return temperature gauges, and 1" BSP swivel unions, it provides fail-safe temperature regulation for manifolds from 2 to 12 ports.

COMPLETE MANIFOLD MIXING STATIONA-RATED 6M CIRCULATOR35°C - 65°C FAIL-SAFE BLENDING210MM MANIFOLD DROP-INDUAL DIAL THERMOMETERS

Trade Engineering Standards & Hydraulic Application

In hydronic underfloor heating installations, matching the circulation pump's head and volumetric flow rate to circuit pressure drop is essential to prevent cold spots, actuator noise, and premature component wear. The Underfloor Heating Blending Valve and Circulation Pump Set (Complete Station) is precision-engineered to British Standard BS EN 1264 and CIBSE hydronic sizing standards, guaranteeing balanced loop flow across modern UK domestic and commercial heating systems.

Engineering Specifications & Technical Standards

Parameter Specification Standard
Model / SKUZL-2536W Complete Manifold Pump Station
Thermostatic Mixing Range35°C to 65°C (Precision Wax Thermostatic Core)
Manifold Bar Spacing210mm Centres (Standard UK Manifold Fitting)
Manifold Connectors1" BSP Male Swivel Union Connections with Flat EPDM Gaskets
Primary Boiler Feeds3/4" BSP Female Connections
Circulation PumpA-Rated High Efficiency 6m Low-Energy Circulator
Temperature InstrumentationTwin Integrated Flow & Return Dial Thermometers (0-80°C)
Check ValveInternal Spring Check Valve to Prevent Hydraulic Reverse Flow
Body MetallurgyDezincification Resistant CW617N Brass
Max Static Pressure10 Bar (PN10 Static Pressure Test Rating)
Directives & StandardsBS EN 1264, ErP EEI ≤ 0.20, CE, UKCA Approved

Step-by-Step Installation & Commissioning Protocol

  1. Hydraulic Isolation & Depressurisation: Close manifold isolation ball valves and isolate primary boiler feeds before loosening union nuts. Have a trade catchment tray ready for residual water.
  2. Gasket Seating & Mechanical Fit: Inspect flat union mating faces. Insert fresh 1½" EPDM sealing washers. Position pump body strictly with the motor shaft horizontal (never pointing vertically up or down) to ensure water-lubricated bearing longevity.
  3. Torque Alignment: Tighten 1½" BSP union nuts by hand, then secure with adjustable pump spanners to recommended torque (approximately 45–55 Nm). Do not overtighten or pinch the rubber gasket.
  4. Electrical Termination: Wire live, neutral, and earth into the manifold wiring centre or 230V room thermostat switched live output. Verify earth continuity in accordance with BS 7671 (IET Wiring Regulations 18th Edition).
  5. Venting & Air Purging: Fill the manifold circuits loop by loop until flowmeter sight glasses run crystal clear of trapped microbubbles. Power on pump and allow automatic air-venting routine to complete before locking final operational mode.
  6. Flow Balancing: Calibrate flowmeters on each manifold port according to CIBSE design calculation sheets (typically 1.5 to 2.5 Litres/min per loop depending on loop length).

Frequently Asked Questions: Underfloor Heating Blending Valve and Circulation Pump Set (Complete Station)

What manifolds does this complete mixing station fit?

It fits all standard UK underfloor heating manifolds with 210mm vertical bar centres and 1" BSP connections, including MEP Stock stainless steel manifolds, Emmeti, Uponor, and Myson.

How accurate is the thermostatic mixing valve?

The valve maintains mixed water temperature within ±2°C of the setpoint regardless of fluctuations in boiler primary supply temperature or water pressure.

What safety mechanisms protect wooden or delicate floor coverings?

The mixing valve incorporates a fail-safe mechanical shut-off: if cold water supply fails or water exceeds the setpoint, the thermal core automatically shuts down flow to prevent floor damage.

Does this set include isolation valves for maintenance?

Yes, it includes integrated union connections and isolation capabilities, allowing straightforward servicing of the pump without draining down floor circuits.

Can this station be wired to a central heating wiring centre?

Yes, the circulation pump connects to standard 230V wiring centres (such as MEP Stock, Heatmiser, or Salus) triggered when any individual zone room thermostat calls for heat.

Is trade volume pricing available for heating contractors?

Yes, trade accounts and bulk contractors benefit from ex-VAT volume pricing and guaranteed next-day delivery across the UK.

Order the Underfloor Heating Blending Valve and Circulation Pump Set (Complete Station) with Trade Delivery

Genuine heating and hydronic supplies in stock for immediate dispatch. Backed by full UK manufacturer warranty and dedicated technical support.